Fire extinguishing system manual books tagged fire. The kidde dry chemical agents shall be contained in one or more stored pressure dot rated steel cylinder and valve assemblies. The control panel is approved for use in suppression systems covered by nfpa codes 12, 12a, 17, 17a, and 2001. The test cartridge is used for functional testing of the kidde whdr wet chemical system and ind dry chemical system. Cylinders requiring an external source to pressurize the agent shall not be acceptable. The kidde ind dry chemical system, provides 24hour fire protection for a wide variety of industrial processes, equipment, machinery and paint spray booth applications. The badger family of portable fire extinguishers is perfect for all your commercial and industrial needs. Kidde model ind instruction manual and all applicable addenda. Kidde ind dry chemical fire suppression systems ttlcompany. Our flexibility is partially due to the variety of choice in surfactant used for fire suppression, with products utilizing powder, dual agent, or gas.
The kidde ind dry chemical system offers the choice of two dry chemical agents effective on class a, b and c fires. The manual station can be of either electric or mechanical means. The system can be activated mechanically from manual release, thermobulb links, and fusible links. These are preengineered systems, each cylinder being used to protect a designated area. Kidde ind dry chemical system for vehicle spray booths design, installation, operation and maintenance diom manual part number 83036001, and all applicable addenda, as identified by underwriters laboratories file no. Economical protection for paint booths and industrial process equipment. Stored pressure dry chemical hand portable fire extinguishers pro line 16 pages fire extinguisher kidde home hero owners manual.
Fire extinguisher kidde pro line service manual stored pressure dry chemical hand portable fire extinguishers pro line 16 pages fire extinguisher kidde xl2. It meets requirements of nfpa 72 and is ul listed per standard 864. Cease fire has the correct fire suppression system for you. The use of at least one manual station for system release must be installed in accordance with nfpa 17. The system includes detectors, a control unit, agent storage cylinders, piping and discharge nozzles. Minimax mx 1230 fire extinguishing system, uses 3m novec 1230 fire protection fluid. The system shall use kidde bc sodium bicarbonate dry chemical agent. The kidde fire systems ind dry chemical system provides 24hour fire protection for a wide variety of industrial processes, equipment, machinery and paint spray booth applications. Adding in the ability to choose between early detection systems or localizedheat activated systems. Stored pressure dry chemical hand portable fire extinguishers pro line 16 pages fire extinguisher kidde xl2. Kidde fire systems offers a wide range of proven technologies to serve the diverse needs of virtually every industry. The kidde ind dry chemical system is your best choice for protection of any industrial process or machinery where hazardous liquids or hazardous materials are involved.
The design, piping and installation shall be in accor dance with nfpa 17 and the kidde. Kidde ind systems, with abc or bc dry chemical agents, are listed by underwriters laboratories, inc. The kidde ind system is available in two basic configurations. The ansul ind x industrial fire suppression system is an automatic fire suppression system using foray dry chemical agent for class a, b and c fires and plusfifty c dry chemical agent for class b and c fires, stored under pressure using dry nitrogen gas at 450 psi 31. For fire hazards found in industrial settings, ansul dry chemical systems provide the flexibility based on the size and configuration of the application. Natural 4 x o 5 mm 2 1 3 4 item description 1 12 emt connector, port for manual wire release. The cartridge has a red band and is labeled test cartridge as shown in figure 3. A local application system is designed to protect a specific piece of equipment, while a total flood system is recommended for protection of enclosed rooms or. Kidde ind dry chemical whdr wet chemical certified. Minimax clean agent fire suppression fire alarm system.
Dry chemical fire suppression system kidde fire systems. Kidde wet chemical system xv control system external view cast aluminium 188300pdsa001 xv control system 188300 front view in set position with cover set 240 210 back view 194,30 8,60 111,50 weight. The manual station can be of either electric or mechanical. Kidde automotive extinguisher owners manual pdf download. Contact us for a noobligation quote for kidde ind dry chemical and other fire. Kidde kitchen fire extinguisher owners manual pdf download. Related manuals for kidde automotive extinguisher fire extinguisher kidde pro line service manual stored pressure dry chemical hand portable fire extinguishers pro line 16 pages. Industry guard industrial fire suppression systems are made with optimum safety, flexibility, ease and affordability in mind. The ind dry chemical system offers the choice of two dry chemical agents effective on class a, b and c fires. The kidde model ind cylinders shall be of the appropriate type, quantity, and size for the protected hazard areas, as required by the kidde diom manual. The system shall use kidde abc monoammonium phosphate or bc sodium bicarbonate dry chemical agents. The system includes detectors, a control unit, agent storage cylinders, piping and discharge nozzles and offers the choice of two dry chemical agents effective on class a, b and. The kidde fire systems ind dry chemical system is your best choice for protection of any industrial process or machinery where hazardous liquids or hazardous materials are involved. Dry chemical fire suppression system kidde fire systems dry chemical fire suppression system dry chemical fire suppression systems provide 247 fire protection for industrial process equipment in applications ranging from paint spray booths to generator rooms to flammable liquid storage containers.
Kidde 2 times industrial dry chemical fire suppression system installation, operation and maintenance manual field use copy by. Kidde aegis conventional fire alarmsuppression control. The system can be activated electrically with a 24 vdc compatible alarm control panel that is tested and listed with the kidde xv control system. The aries fire alarmsuppression system control unit is a compact control unit that provides one signaling line circuit, four notificationappliance circuits, two releasing circuits, and four onboard relays. This sleek control unit easily fits between studs of a. Our products, combined with our highly skilled, worldwide installation and service network, allow us to provide you with a total system solution to solve your fire protection needs. The kidde ind dry chemical system provides 24hour fire protection for a wide variety of industrial processes, equipment, machinery and paint spray booth applications. The kidde fire systems ind system uses class abc dry chemical to suppress fire in vehicle spray booths. Both automatic detection and manual release devices are used on control panels. Two distinct automatic mechanical detection lines fusible links or thermobulb links optional electrical solenoid. Compatible with legacy fenwal initiators and chemetron solenoids.
The control panel is approved for use in suppression systems covered by. Kidde industrial dry chemical fire suppression system for paint spray booths. Kidde ind dry chemical system for vehicle spray booths system diom kidde ind dry chemical system for vehicle spray booths installation, operation and maintenance manual code. May 25, 2016 compatible with kidde fire systems ads and ecs clean agent, inert gas, hpco2, cardox lpco2, whdr wet chemical and ind dry chemical suppression systems. Cease fire is the only company in the world with the unique dual agent technology. The system nitrogen cartridge pn 87120043001 is required for actuation and full discharge or puff tests.
Ansul indx industrial fire suppression system clean. Kidde fire systems has identified an issue with the detection line cable spools on older model xv control systems, pn 87120099001, used in kidde whdr wet chemical and ind dry chemical fire suppression systems. The ind system is available in two basic configurations. Ind dry chemical fire system kidde fire systems kidde fenwal. Kidde preengineered industrial dry chemical fire suppression. Kidde ind dry chemical system for industrial applications. Rugged kidde ind systems are recommended for all types of industrial fire protection. The gemini ii is also listed for sprinkler supervisory service and for halon, foamfoamwater and delugepreaction systems. Kidde aegis conventional fire alarmsuppression control unit. Kidde ind dry chemical paint booth fire suppression systems. The kidde fire systems ind dry chemical system provides 24hour fire protection for a wide variety of industrial processes, equipment, machinery and paint. The cylinders shall have a tinnickel alloy plated brass valve, with pressure gauge. The aegis can be used to control kidde s full line of suppression systems kidde s ecs clean agents, carbon dioxide, whdr wet chemical and ind dry chemical, as well as sprinkler supervisory, delugepreaction, foam and foamwater systems. Actuation parameters for industry guard industrial dry chemical and openface spray booth systems operating temperature range number of extinguishing system cylinders maximum total length copper actuation tubing minimum total length of copper actuation tubing40f to 120f 40c to 49c 114 166 ft.
Resin material used in spool manufacturing between january 2008 through june. Badgers industry guard dry chemical fire suppression system uses dry chemical compounds that, pound for pound, suppress more fire than any other agent. Model ind dry chemical fire suppression system for industrial. This fluid will not damage electronics and will leave no residue behind. Ul 300, underwriters laboratories standard for fire extinguishing systems for. Both systems provide automatic or manual operation and detectionalarmrelease capabilities. Walter kidde gas station dry chemical fire suppression system.
The kidde model ind cylinder s shall be of the appropriate type, quantity, and size for the protected hazard areas, as required by the kidde diom manual. Kidde ads p 7576 kidde hp co2 system p 7778 pressure relief dampers p 79 wet chemical systems p 8081 dry chemical systems p 82 vehicle systems p 83 statx aerosol systems p 8485 fixed foam systems p 86105 marioff hifog p 106108 smoke alarms p 110114 fire blankets p 115 fire extinguishers p 116118. Kidde s whdr system provides 24hour automatic or manual protection for commercial cooking areas. Ceasefire preengineered fire suppression control fire systems. Poundforpound, dry chemical suppresses more fire than any other agent, providing both rapid suppression and protection against fire reignition. Preengineered ind dry chemical system kidde fenwal.
Kidde ind industrial fire suppression systems monroe. More kidde marine systems kidde offers a variety of systems designed specifically for the marine market under the brand name, kidde marine. Dry chemical systems kidde dry chemical systems kidde ind system used for a variety of industrial processess and the kidde kvs used to protect large vehicle systems. Main control panel mcp mcp power supply the mcp operates on 120240 vac 5060 hz power supply. A local application system is designed to protect a specific piece of equipment, while a total flood system is recommended for protection of enclosed rooms or spaces. More kidde marine systems kidde offers a variety of systems designed specifically for the marine market under the brand name, kidde. Fm approved for ind systems description the kidde xv control system is a compact, versatile unit used to actuate agent cylinders on kidde whdr and ind preengineered fire suppression systems. Related manuals for kidde kitchen fire extinguisher. Nfpa 17 standard for dry chemical extinguishing systems. It also has a higher safety margin than any other clean agents on the market, making it extremely safe for people working in protected areas. Installation, operation, and maintenance of automatic model ind 50dc fusible, electic, or rate of rise actuation, dry chemical preengineered fire protection for local application and total flooding by rune t.
956 214 319 324 896 775 478 864 1684 152 28 1056 1688 1547 846 1082 1798 1439 1328 973 1802 128 1168 868 980 1169 1476 125 1474 269 846 232 664 1330 1354 1492 761 1463